Abstract
We report the retrieval of an aspirated laryngoscope bulb using a fiberbronchoscope. This case combines a previously undescribed complication of endotracheal intubation and the problems created by an unexpected endobronchial foreign body in a multiple trauma patient.
Original language | English |
---|---|
Pages (from-to) | 143-144 |
Number of pages | 2 |
Journal | Intensive Care Medicine |
Volume | 7 |
Issue number | 3 |
DOIs | |
State | Published - May 1981 |
Externally published | Yes |
Keywords
- Bronchoscopy
- Foreign body
- Intubation