T1 - Fellow eye comparison of corneal thickness and curvature in descemet membrane endothelial keratoplasty and descemet stripping automated endothelial keratoplasty
AU - Goldich, Yakov
AU - Artornsombidth, Pichaporn
AU - Avni-Zauberman, Noa
AU - Perez, Mauricio
AU - Ulate, Randall
AU - Elbaz, Uri
AU - Rootman, David S.
PY - 2014/6
Y1 - 2014/6
N2 - Purpose: To compare posterior corneal curvature in the fellow eye of the same patients after Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK). Methods: This retrospective, case series comparative study included consecutive patients who underwent DSAEK in one eye and DMEK in the fellow eye. Each eye underwent corneal evaluation with Pentacam HR (Oculus, Wetzlar, Germany). Postoperative corneal curvature, corneal thickness, and visual acuity were assessed. Results: Twenty eyes of 10 patients (5 women and 5 men) aged 72.5 ± 13.5 (range, 42-87) years were included. No significant differences were observed between front flat K's (43.01 ± 1.6 vs. 43.5 ± 0.9, P = 0.27) and front steep K's (44.17 ± 1.5 vs. 44.52 ± 0.7, P = 0.39) in DMEK vs. DSAEK eyes, accordingly. Posterior curvature was statistically significantly flatter in DMEK compared with DSAEK eyes; back flat K's (-6.30 ± 0.2 vs. -6.84 ± 0.6, P = 0.012), back steep K's (-6.64 ± 0.1 vs. -7.2 ± 0.3, P = 0.03), and back Km (-6.45 ± 0.1 vs. -6.99 ± 0.4, P = 0.005), accordingly. Corneas in DMEK eyes were significantly thinner than in DSAEK eyes (541.0 ± 61 vs. 627.9 ± 70 μm, P = 0.007). Conclusions: Eyes that underwent DSAEK surgery have thicker corneas with steeper posterior corneal curvature than fellow eyes that underwent DMEK. This difference may explain the hyperopic shift commonly observed after DSAEK and should be considered when choosing an intraocular lens for cataract surgery.
AB - Purpose: To compare posterior corneal curvature in the fellow eye of the same patients after Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK). Methods: This retrospective, case series comparative study included consecutive patients who underwent DSAEK in one eye and DMEK in the fellow eye. Each eye underwent corneal evaluation with Pentacam HR (Oculus, Wetzlar, Germany). Postoperative corneal curvature, corneal thickness, and visual acuity were assessed. Results: Twenty eyes of 10 patients (5 women and 5 men) aged 72.5 ± 13.5 (range, 42-87) years were included. No significant differences were observed between front flat K's (43.01 ± 1.6 vs. 43.5 ± 0.9, P = 0.27) and front steep K's (44.17 ± 1.5 vs. 44.52 ± 0.7, P = 0.39) in DMEK vs. DSAEK eyes, accordingly. Posterior curvature was statistically significantly flatter in DMEK compared with DSAEK eyes; back flat K's (-6.30 ± 0.2 vs. -6.84 ± 0.6, P = 0.012), back steep K's (-6.64 ± 0.1 vs. -7.2 ± 0.3, P = 0.03), and back Km (-6.45 ± 0.1 vs. -6.99 ± 0.4, P = 0.005), accordingly. Corneas in DMEK eyes were significantly thinner than in DSAEK eyes (541.0 ± 61 vs. 627.9 ± 70 μm, P = 0.007). Conclusions: Eyes that underwent DSAEK surgery have thicker corneas with steeper posterior corneal curvature than fellow eyes that underwent DMEK. This difference may explain the hyperopic shift commonly observed after DSAEK and should be considered when choosing an intraocular lens for cataract surgery.
KW - Descemet membrane endothelial keratoplasty
KW - Descemet stripping automated endothelial keratoplasty
KW - Pentacam
KW - corneal curvature
UR - http://www.scopus.com/inward/record.url?scp=84900798802&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000000118
DO - 10.1097/ICO.0000000000000118
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 24699562
AN - SCOPUS:84900798802
SN - 0277-3740
VL - 33
SP - 547
EP - 550
JO - Cornea
JF - Cornea
IS - 6
ER -