TY - JOUR
T1 - Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses
AU - Nimri, Revital
AU - Grosman, Benyamin
AU - Roy, Anirban
AU - Nir, Judith
AU - Fisch Shvalb, Naama
AU - Kurtz, Natali
AU - Loewenthal, Neta
AU - Gillon-Keren, Michal
AU - Muller, Ido
AU - Atlas, Eran
AU - Phillip, Moshe
N1 - Publisher Copyright:
© 2021, Mary Ann Liebert, Inc., publishers.
PY - 2021/4/1
Y1 - 2021/4/1
N2 - Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, which includes several algorithm enhancements and an optional autocorrection bolus mode. Methods: Twelve adolescents and young adults (eight females) with type 1 diabetes [median (interquartile range)] aged 16.6 (15.9, 18.2) years and diabetes duration of 7.1 (4.7, 8.8) years] participated in this single-arm study. The first stage was a 6-day open-loop run-in period, with the predictive low-glucose suspend feature on. This was followed by 6 days/5 nights in a supervised hotel setting, using the AHCL system, including closed-loop challenges (missed meal bolus, late meal bolus, and physical activity); and finally, 3 weeks with unrestricted home use. Glycemic parameters were compared between the open-loop and closed-loop periods. Results: Participants spent 93.3% (4.7) of the time in SmartGuard™ Auto Mode. Hemoglobin A1C levels decreased from median (interquartile range) 7.1% (6.7, 7.9) at baseline to 6.8% (6.6, 7.4) at study end, after 4 weeks (P = 0.0027). Time in range (TIR) (70-180 mg/dL) was 68.4% (10.6) and time below 70 mg/dL was 4% (3.5) during open-loop; and 74% (6.1) and 2.6% (1.9), respectively, during the closed-loop at home phase (P = 0.06, P = 0.27). TIR increased during the nighttime, from 64.6% (17.4) to 80.7% (7.8), P = 0.007, without change in time below 70 mg/dL (P = 0.15). No serious adverse events occurred. Conclusions: The new AHCL system demonstrated safety and effectiveness in controlling day and night glucose levels.
AB - Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, which includes several algorithm enhancements and an optional autocorrection bolus mode. Methods: Twelve adolescents and young adults (eight females) with type 1 diabetes [median (interquartile range)] aged 16.6 (15.9, 18.2) years and diabetes duration of 7.1 (4.7, 8.8) years] participated in this single-arm study. The first stage was a 6-day open-loop run-in period, with the predictive low-glucose suspend feature on. This was followed by 6 days/5 nights in a supervised hotel setting, using the AHCL system, including closed-loop challenges (missed meal bolus, late meal bolus, and physical activity); and finally, 3 weeks with unrestricted home use. Glycemic parameters were compared between the open-loop and closed-loop periods. Results: Participants spent 93.3% (4.7) of the time in SmartGuard™ Auto Mode. Hemoglobin A1C levels decreased from median (interquartile range) 7.1% (6.7, 7.9) at baseline to 6.8% (6.6, 7.4) at study end, after 4 weeks (P = 0.0027). Time in range (TIR) (70-180 mg/dL) was 68.4% (10.6) and time below 70 mg/dL was 4% (3.5) during open-loop; and 74% (6.1) and 2.6% (1.9), respectively, during the closed-loop at home phase (P = 0.06, P = 0.27). TIR increased during the nighttime, from 64.6% (17.4) to 80.7% (7.8), P = 0.007, without change in time below 70 mg/dL (P = 0.15). No serious adverse events occurred. Conclusions: The new AHCL system demonstrated safety and effectiveness in controlling day and night glucose levels.
KW - Adolescents
KW - Closed-loop system
KW - Continuous glucose monitoring
KW - Insulin pump
KW - Pediatric
KW - Type 1 diabetes
UR - https://www.scopus.com/pages/publications/85103721282
U2 - 10.1089/dia.2020.0448
DO - 10.1089/dia.2020.0448
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 33185480
AN - SCOPUS:85103721282
SN - 1520-9156
VL - 23
SP - 268
EP - 276
JO - Diabetes Technology and Therapeutics
JF - Diabetes Technology and Therapeutics
IS - 4
ER -