TY - JOUR
T1 - Evaluation of a portable differential continuous flow centrifuge for concentration of Cryptosporidium oocysts and Giardia cysts from water
AU - Zuckerman, U.
AU - Armon, R.
AU - Tzipori, S.
AU - Gold, D.
PY - 1999
Y1 - 1999
N2 - A portable device was developed and assembled from a stationary differential continuous flow centrifuge usually employed for blood cell separation, for the purpose of concentrating Cryptosporidium and Giardia from large volumes of water. Following compaction onto the wall of the disposable plastic centrifuge bowl and aspiration of residual water, the oocysts and cysts were dislodged by injection of a 20 ml solution containing 0.01% Tween- 80 and 1% SDS and vigorous shaking. Following aspiration, the oocysts were pelleted, reacted with specific FITC-conjugated monoclonal antibodies, and enumerated via fluorescence microscopy. The entire procedure required about 2 h. Initially, 55% and 87% of Cryptosporidium oocysts and Giardia cysts, respectively, were recovered from 45 litres of tap water, and 27% and 57%, respectively, from river water. Adjustments in centrifuge speed and flow rates improved recovery to about 90% for Cryptosporidium oocysts and hence, this method compared favourably with the recently developed calcium carbonate flocculation method. It was superior in time requirement and volume flexibility, and showed a distinct advantage over the standard cartridge filtration method in all respects. The continuous flow centrifugation equipment is compact, mobile, flexible, and yields reproducibly high recovery rates. The ease of handling, speed of performance and minimal requirements for post-concentration equipment, reagents and labour make the system highly cost-effective. It appears to offer an improved method, well suited for use by water utilities for monitoring the burden of water-borne protozoan pathogens.
AB - A portable device was developed and assembled from a stationary differential continuous flow centrifuge usually employed for blood cell separation, for the purpose of concentrating Cryptosporidium and Giardia from large volumes of water. Following compaction onto the wall of the disposable plastic centrifuge bowl and aspiration of residual water, the oocysts and cysts were dislodged by injection of a 20 ml solution containing 0.01% Tween- 80 and 1% SDS and vigorous shaking. Following aspiration, the oocysts were pelleted, reacted with specific FITC-conjugated monoclonal antibodies, and enumerated via fluorescence microscopy. The entire procedure required about 2 h. Initially, 55% and 87% of Cryptosporidium oocysts and Giardia cysts, respectively, were recovered from 45 litres of tap water, and 27% and 57%, respectively, from river water. Adjustments in centrifuge speed and flow rates improved recovery to about 90% for Cryptosporidium oocysts and hence, this method compared favourably with the recently developed calcium carbonate flocculation method. It was superior in time requirement and volume flexibility, and showed a distinct advantage over the standard cartridge filtration method in all respects. The continuous flow centrifugation equipment is compact, mobile, flexible, and yields reproducibly high recovery rates. The ease of handling, speed of performance and minimal requirements for post-concentration equipment, reagents and labour make the system highly cost-effective. It appears to offer an improved method, well suited for use by water utilities for monitoring the burden of water-borne protozoan pathogens.
UR - http://www.scopus.com/inward/record.url?scp=0032977620&partnerID=8YFLogxK
U2 - 10.1046/j.1365-2672.1999.00776.x
DO - 10.1046/j.1365-2672.1999.00776.x
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:0032977620
SN - 1364-5072
VL - 86
SP - 955
EP - 961
JO - Journal of Applied Microbiology
JF - Journal of Applied Microbiology
IS - 6
ER -