Abstract
The effect of porous substrate characteristics on the overall performance of a composite reverse osmosis membrane assembly is investigated for the two most representative concepts, classified as the parallel and radial flow pattern systems. Pressure drop, as well as flux declinecurves, as functions of physical parameters of the system are presented.
Original language | English |
---|---|
Pages (from-to) | 261-275 |
Number of pages | 15 |
Journal | Desalination |
Volume | 8 |
Issue number | 3 |
State | Published - 1970 |