TY - JOUR
T1 - Effect of fibrotic capsule debridement during generator replacement on cardiac implantable electronic device infection risk
AU - Goldenberg, Gustavo R.
AU - Barsheshet, Alon
AU - Bishara, Jihad
AU - Kadmon, Ehud
AU - Omelchencko, Alex
AU - Strasberg, Boris
AU - Golovchiner, Gregory
N1 - Publisher Copyright:
© 2019, Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2020/6/1
Y1 - 2020/6/1
N2 - Background: Cardiovascular implantable electronic device (CIED) replacement is increasingly common. It has been proposed that capsule removal at the time of CIED replacement may reduce infection rates. In this study, we aimed to assess how pocket capsule removal impacted infection rates in patients undergoing CIED replacement. Methods: We retrospectively reviewed the medical records of patients who underwent CIED replacement from 2006 to 2016 at a single centre. We retrieved patient data, procedure details, and clinical outcomes. To evaluate the relationship between capsule removal and CIED infection, we used the Cox proportional hazard model, with adjustment for multiple variables. Results: During the study period, 773 patients underwent device replacement. Of these patients, 194 (25%) underwent capsule debridement during the replacement procedure. The mean patient age was 75 ± 15 years, and 281 (36.3%) were females. The replaced CIEDs included DDD pacemakers (32%), VDD pacemakers (15%), VVI/AAI pacemakers (13%), defibrillators (22%), and cardiac resynchronization therapy devices (CRT-D/P) (17%). During an average follow-up of 3.6 years, 42 (5%) patients experienced a CIED infection. Multivariate analysis revealed that patients who underwent capsule removal had a significantly lower risk of CIED infection, with a hazard ratio of 0.32 (95% confidence interval, 0.12–0.83; P = 0.019). Conclusions: Capsule debridement during CIED replacement was associated with a significant reduction of CIED infection risk. There is a need for randomized controlled studies to confirm these findings.
AB - Background: Cardiovascular implantable electronic device (CIED) replacement is increasingly common. It has been proposed that capsule removal at the time of CIED replacement may reduce infection rates. In this study, we aimed to assess how pocket capsule removal impacted infection rates in patients undergoing CIED replacement. Methods: We retrospectively reviewed the medical records of patients who underwent CIED replacement from 2006 to 2016 at a single centre. We retrieved patient data, procedure details, and clinical outcomes. To evaluate the relationship between capsule removal and CIED infection, we used the Cox proportional hazard model, with adjustment for multiple variables. Results: During the study period, 773 patients underwent device replacement. Of these patients, 194 (25%) underwent capsule debridement during the replacement procedure. The mean patient age was 75 ± 15 years, and 281 (36.3%) were females. The replaced CIEDs included DDD pacemakers (32%), VDD pacemakers (15%), VVI/AAI pacemakers (13%), defibrillators (22%), and cardiac resynchronization therapy devices (CRT-D/P) (17%). During an average follow-up of 3.6 years, 42 (5%) patients experienced a CIED infection. Multivariate analysis revealed that patients who underwent capsule removal had a significantly lower risk of CIED infection, with a hazard ratio of 0.32 (95% confidence interval, 0.12–0.83; P = 0.019). Conclusions: Capsule debridement during CIED replacement was associated with a significant reduction of CIED infection risk. There is a need for randomized controlled studies to confirm these findings.
KW - Capsule debridement
KW - Cardiac implantable electronic device
KW - Infection
KW - Outcomes
UR - http://www.scopus.com/inward/record.url?scp=85067875731&partnerID=8YFLogxK
U2 - 10.1007/s10840-019-00581-4
DO - 10.1007/s10840-019-00581-4
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 31227978
AN - SCOPUS:85067875731
SN - 1383-875X
VL - 58
SP - 113
EP - 118
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
IS - 1
ER -