TY - JOUR
T1 - Double-Balloon Kyphoplasty Results in Better Radiographic Outcomes Than a Single-Balloon Kyphoplasty in Treating Osteo-Porotic Spinal Fractures
AU - Lotan, Raphael
AU - Haimovich, Yaron
AU - Schorr, Louis
AU - Goldstein, Adam Lee
AU - Hershkovich, Oded
N1 - Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/6/1
Y1 - 2022/6/1
N2 - Background: Studies have found that unilateral and bilateral kyphoplasty have comparable clinical outcomes. Only a few studies have compared the radiographic results of using unilateral vs. simultaneous bilateral approaches. We aimed to examine and compare the radiographic results of unilateral (UKP) vs. bilateral simultaneous double-balloon kyphoplasty (DKP) for treating symptomatic vertebral compression fractures (VCF). Methods: A retrospective cohort of all patients treated for VCF by DKP and UKP over five years in a single medical center. From 2009 to 2012, we routinely performed UKP; from 2012, DKP was the routine due to potential benefits in vertebral realignment. We evaluated pre-and post-surgical fracture characteristics including vertebral height, sagittal and coronal Cobb angle, and fracture reduction. Statistical analysis included a t-test for independent vari-ables and Pearson’s correlation. Results: The study cohort consisted of 81 patients (75.8 years ± 10.86) who underwent surgery, with a total of 119 vertebras. We performed 89 UKP on fractured vertebras and 30 DKP on 30 vertebrae. The UKP average fluoroscopy radiation exposure was 15.8 mGy (±11.5) per level compared to 11.2 mGy (±8.7) for DKP, p = 0.03. DKP showed significant fracture reduction, 2.8 degrees of Cobb angle, equaling the patient positioning effect on fracture reduction. Conclusion: DKP results in better fracture reduction than UKP, and equals the effect of patient positioning without increased radiation exposure or adverse events.
AB - Background: Studies have found that unilateral and bilateral kyphoplasty have comparable clinical outcomes. Only a few studies have compared the radiographic results of using unilateral vs. simultaneous bilateral approaches. We aimed to examine and compare the radiographic results of unilateral (UKP) vs. bilateral simultaneous double-balloon kyphoplasty (DKP) for treating symptomatic vertebral compression fractures (VCF). Methods: A retrospective cohort of all patients treated for VCF by DKP and UKP over five years in a single medical center. From 2009 to 2012, we routinely performed UKP; from 2012, DKP was the routine due to potential benefits in vertebral realignment. We evaluated pre-and post-surgical fracture characteristics including vertebral height, sagittal and coronal Cobb angle, and fracture reduction. Statistical analysis included a t-test for independent vari-ables and Pearson’s correlation. Results: The study cohort consisted of 81 patients (75.8 years ± 10.86) who underwent surgery, with a total of 119 vertebras. We performed 89 UKP on fractured vertebras and 30 DKP on 30 vertebrae. The UKP average fluoroscopy radiation exposure was 15.8 mGy (±11.5) per level compared to 11.2 mGy (±8.7) for DKP, p = 0.03. DKP showed significant fracture reduction, 2.8 degrees of Cobb angle, equaling the patient positioning effect on fracture reduction. Conclusion: DKP results in better fracture reduction than UKP, and equals the effect of patient positioning without increased radiation exposure or adverse events.
KW - balloon kyphoplasty
KW - osteoporotic fractures
KW - vertebral compression fractures
UR - http://www.scopus.com/inward/record.url?scp=85131853478&partnerID=8YFLogxK
U2 - 10.3390/jcm11123407
DO - 10.3390/jcm11123407
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 35743477
AN - SCOPUS:85131853478
SN - 2077-0383
VL - 11
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 12
M1 - 3407
ER -