TY - JOUR
T1 - Distortion product otoacoustic emissions following stapedectomy versus stapedotomy
AU - Migirov, L.
AU - Wolf, M.
PY - 2010/1
Y1 - 2010/1
N2 - Objectives: To evaluate distortion product otoacoustic emissions following stapes surgery in patients with otosclerosis, and to compare in this respect two surgical techniques used in our department.Method: This retrospective study included 17 stapedectomy and 23 stapedotomy patients aged 1668 years who had been followed up for at least 12 months. Distortion product otoacoustic emission results at 2, 3, 4 and 5kHz (i.e.=f2, with 2f1-f2=0.6f2) were obtained pre-operatively and four weeks post-operatively. The control group included 13 volunteers aged 18-50 years with normal hearing and normal otoscopic findings.Results: Distortion product otoacoustic emissions were detected pre-operatively in 34.8 per cent of stapedotomy patients and 29.4 per cent of stapedectomy patients, and post-operatively in 91.3 per cent of stapedotomy patients and 88.2 per cent of stapedectomy patients. The differences between the stapedotomy and stapedectomy groups were statistically insignificant for each tested frequency, both pre- and post-operatively. The patients' post-operative distortion product otoacoustic emission amplitudes were less than those of normal hearing individuals, even in patients with complete airbone gap closure and a significant improvement in hearing.Conclusion: Distortion product otoacoustic emissions were detected in most of our patients following successful stapes surgery, and appeared to be unaffected by the surgical technique or prosthesis used.
AB - Objectives: To evaluate distortion product otoacoustic emissions following stapes surgery in patients with otosclerosis, and to compare in this respect two surgical techniques used in our department.Method: This retrospective study included 17 stapedectomy and 23 stapedotomy patients aged 1668 years who had been followed up for at least 12 months. Distortion product otoacoustic emission results at 2, 3, 4 and 5kHz (i.e.=f2, with 2f1-f2=0.6f2) were obtained pre-operatively and four weeks post-operatively. The control group included 13 volunteers aged 18-50 years with normal hearing and normal otoscopic findings.Results: Distortion product otoacoustic emissions were detected pre-operatively in 34.8 per cent of stapedotomy patients and 29.4 per cent of stapedectomy patients, and post-operatively in 91.3 per cent of stapedotomy patients and 88.2 per cent of stapedectomy patients. The differences between the stapedotomy and stapedectomy groups were statistically insignificant for each tested frequency, both pre- and post-operatively. The patients' post-operative distortion product otoacoustic emission amplitudes were less than those of normal hearing individuals, even in patients with complete airbone gap closure and a significant improvement in hearing.Conclusion: Distortion product otoacoustic emissions were detected in most of our patients following successful stapes surgery, and appeared to be unaffected by the surgical technique or prosthesis used.
KW - Otoacoustic emissions
KW - Otosclerosis
KW - Stapedectomy
UR - http://www.scopus.com/inward/record.url?scp=75149165990&partnerID=8YFLogxK
U2 - 10.1017/S0022215109991150
DO - 10.1017/S0022215109991150
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:75149165990
SN - 0022-2151
VL - 124
SP - 16
EP - 18
JO - Journal of Laryngology and Otology
JF - Journal of Laryngology and Otology
IS - 1
ER -