TY - JOUR
T1 - Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve
T2 - A Pooled Analysis of 5 Prospective Cohort Studies
AU - Witberg, Guy
AU - De Bruyne, Bernard
AU - Fearon, William F.
AU - Achenbach, Stephan
AU - Engstrom, Thomas
AU - Matsuo, Hitoshi
AU - Kornowski, Ran
N1 - Publisher Copyright:
© 2020 American College of Cardiology Foundation
PY - 2020/2/24
Y1 - 2020/2/24
N2 - Objectives: This study sought to assess the diagnostic performance of FFRangio (CathWorks, Kfar Saba, Israel), an angiogram-derived fractional flow reserve (FFR) technology. Background: Despite practice guidelines recommendations, the use of coronary physiologic assessment in daily practice remains low for patients undergoing coronary angiography. Angiogram-derived FFR technologies have the potential to promote the integration of physiologic assessment in daily practice. Methods: The study performed an analysis of pooled patient- and lesion-level data from 5 prospective cohort studies that examined the diagnostic performance of FFRangio compared with the reference standard wire-based FFR. Results: A total of 700 lesions from 588 patients were analyzed. Mean age was 65 years, 71% were men, and 40% presented with acute coronary syndromes. Mean FFR and FFRangio were 0.81 ± 0.12 and 0.81 ± 0.11, with 31.6% and 31.4% of lesions were in the 0.75 to 0.85 range, respectively. When using a binary cutoff FFR value of 0.80, FFRangio showed a sensitivity of 91%, a specificity of 94%, and a diagnostic accuracy of 93%. The mean difference between FFR and FFRangio was 0.00 ± 0.12. The correlation coefficient between FFR and FFRangio was 0.83 (p < 0.001). The C-statistic for FFRangio was 0.95 (p < 0.001). The accuracy of FFRangio was consistent across all subgroups examined. Conclusions: In the largest reported cohort examining the performance of angiogram-derived FFR technology, FFRangio showed excellent diagnostic performance, which was robust and consistent across all patient and lesion subgroups. Additional studies are needed allow FFRangio and fulfill its potential expand the implementation of functional assessment of coronary lesions in routine clinical practice.
AB - Objectives: This study sought to assess the diagnostic performance of FFRangio (CathWorks, Kfar Saba, Israel), an angiogram-derived fractional flow reserve (FFR) technology. Background: Despite practice guidelines recommendations, the use of coronary physiologic assessment in daily practice remains low for patients undergoing coronary angiography. Angiogram-derived FFR technologies have the potential to promote the integration of physiologic assessment in daily practice. Methods: The study performed an analysis of pooled patient- and lesion-level data from 5 prospective cohort studies that examined the diagnostic performance of FFRangio compared with the reference standard wire-based FFR. Results: A total of 700 lesions from 588 patients were analyzed. Mean age was 65 years, 71% were men, and 40% presented with acute coronary syndromes. Mean FFR and FFRangio were 0.81 ± 0.12 and 0.81 ± 0.11, with 31.6% and 31.4% of lesions were in the 0.75 to 0.85 range, respectively. When using a binary cutoff FFR value of 0.80, FFRangio showed a sensitivity of 91%, a specificity of 94%, and a diagnostic accuracy of 93%. The mean difference between FFR and FFRangio was 0.00 ± 0.12. The correlation coefficient between FFR and FFRangio was 0.83 (p < 0.001). The C-statistic for FFRangio was 0.95 (p < 0.001). The accuracy of FFRangio was consistent across all subgroups examined. Conclusions: In the largest reported cohort examining the performance of angiogram-derived FFR technology, FFRangio showed excellent diagnostic performance, which was robust and consistent across all patient and lesion subgroups. Additional studies are needed allow FFRangio and fulfill its potential expand the implementation of functional assessment of coronary lesions in routine clinical practice.
KW - coronary heart disease
KW - coronary physiology
KW - fractional flow reserve
UR - http://www.scopus.com/inward/record.url?scp=85079126533&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2019.10.045
DO - 10.1016/j.jcin.2019.10.045
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 32007461
AN - SCOPUS:85079126533
SN - 1936-8798
VL - 13
SP - 488
EP - 497
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 4
ER -