Deficiencies in root canal fillings subsequent to adaptive instrumentation of oval canals

Ajinkya M. Pawar, Anuj Bhardwaj, Kulvinder S. Banga, Gurdeep Singh, Anda Kfir, Alexander Maniangat Luke*, Vialyne Dinata, Dian Agustin Wahjuningrun*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

The purpose of this study was to explore the influence of instrumentation and the potential for debris deposition using XP-endo shaper plus (XP-SP) and full-sequence SAF (F-SAF) on the adaption of thermoplastic root canal fillings in oval canals. Following the manufacturer’s instructions, ninety human permanent mandibular incisors with a single oval canal 6 mm from the apex (verified using pre-operative CBCT scanning) were instrumented with XP-SP and F-SAF. Obtura III Max apparatus was used for root canal obturation without the use of a root canal sealer. The roots were then sectioned 6 mm from the apex and examined with a digital stereomicroscope at x25 magnification to assess the root canal fillings. The F-SAF was associated with a significantly higher (p < 0.01) percentage of entire adaptation of the root fillings (76%) compared to the XP-SP (57%). Furthermore, the XP-SP group was also associated with higher (p < 0.01) defective obturation with debris at 17% and with voids at 26%. However, the F-SAF had lower percentages of defective obturations (7% with debris and 17% with voids). The quality of obturation of oval canals instrumented using full-sequence SAF was better.

Original languageEnglish
Article number1074
JournalBiology
Volume10
Issue number11
DOIs
StatePublished - Nov 2021

Keywords

  • Adaptive files
  • Debris
  • Root canal instrumentation
  • Self-adjusting files
  • XP-endo files

Fingerprint

Dive into the research topics of 'Deficiencies in root canal fillings subsequent to adaptive instrumentation of oval canals'. Together they form a unique fingerprint.

Cite this