Coronary Access Following Redo TAVR: Impact of THV Design, Implant Technique, and Cell Misalignment

David Meier, Mariama Akodad, Uri Landes, Aaron M. Barlow, Andrew G. Chatfield, Althea Lai, Georgios Tzimas, Gilbert H.L. Tang, Thomas Puehler, Georg Lutter, Jonathon A. Leipsic, Lars Søndergaard, David A. Wood, John G. Webb, Stephanie L. Sellers, Janarthanan Sathananthan*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Background: The implications and potential challenges of coronary access after redo transcatheter aortic valve replacement (TAVR) are unknown. Objectives: The authors sought to evaluate the impact of different transcatheter heart valve (THV) designs, neoskirt height, implant technique, and cell misalignment on coronary access after redo TAVR. Methods: Different THV designs (Sapien 3 [Edwards Lifesciences LLC], Evolut Pro [Medtronic], ACURATE neo [Boston Scientific Corporation], and Portico [Abbott Structural Heart]) and sizes were implanted inside Sapien XT (Edwards Lifesciences LLC) and Evolut R (Medtronic) THVs, which were modeled as the “failed” THVs, at different implant depths. Valve combinations underwent micro–computed tomography to determine the neoskirt height and dimensions of the lowest accessible cell for potential coronary access. This was compared with dimensions of 6-F/7-F/8-F coronary guiding catheters. Results: Redo TAVR combinations resulted in a wide range of neoskirt heights (15.4-31.6 mm) and a variable diameter of the lowest accessible cell (1.9-21.8 mm). An ACURATE neo implanted in a Sapien XT resulted in the largest accessible cells, whereas a Portico implanted in a Sapien XT resulted in the lowest neoskirt heights. The smallest accessible cell was observed in the Evolut Pro–in–Evolut R configuration with higher neoskirt heights. Redo TAVR in a tall frame valve with supra-annular leaflets caused a taller neoskirt height. In Evolut-in-Evolut combinations, misalignment of the cells of the 2 THVs reduced the cell area by 30% to 50% compared with an aligned configuration. Conclusions: This study demonstrates that different redo TAVR combinations are not equivalent in terms of future coronary access. Redo TAVR using a tall frame valve in a failed tall frame valve and misaligned cells may lead to potentially challenging coronary access.

Original languageEnglish
Pages (from-to)1519-1531
Number of pages13
JournalJACC: Cardiovascular Interventions
Volume15
Issue number15
DOIs
StatePublished - 8 Aug 2022

Funding

FundersFunder number
Edwards Lifesciences and Abbott
Fondation Vaudoise de Cardiologie
John Ormiston Scholarship
MUSE Explore
New Zealand Heart Foundation
SICPA Foundation
ViVitro Labs
Abbott Laboratories
Medtronic
Edwards Lifesciences
Boston Scientific Corporation
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungP2LAP3_199561
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Fédération Française de Cardiologie
Biotronik

    Keywords

    • TAVR
    • coronary access
    • redo-TAVR
    • valve-in-valve

    Fingerprint

    Dive into the research topics of 'Coronary Access Following Redo TAVR: Impact of THV Design, Implant Technique, and Cell Misalignment'. Together they form a unique fingerprint.

    Cite this