TY - JOUR
T1 - Control of knee coronal plane moment via modulation of center of pressure
T2 - A prospective gait analysis study
AU - Haim, Amir
AU - Rozen, Nimrod
AU - Dekel, Samuel
AU - Halperin, Nachum
AU - Wolf, Alon
PY - 2008/10/20
Y1 - 2008/10/20
N2 - Objectives: Footwear-generated biomechanical manipulations (e.g., wedge insoles) have been shown to reduce the magnitude of adduction moment about the knee. The theory behind wedged insoles is that a more laterally shifted location of the center of pressure reduces the distance between the ground reaction force and the center of the knee joint, thereby reducing adduction moment during gait. However, the relationship between the center of pressure and the knee adduction moment has not been studied previously. The aim of this study was to examine the association between the location of the center of pressure and the relative magnitude of the knee adduction moment during gait in healthy men. Methods: A novel foot-worn biomechanical device which allows controlled manipulation of the center of pressure location was utilized. Twelve healthy men underwent successive gait analysis testing in a controlled setting and with the device set to convey three different para-sagittal locations of the center of pressure: neutral, medial offset and lateral offset. Results: The knee adduction moment during the stance phase significantly correlated with the shift of the center of pressure from the functional neutral sagittal axis in the coronal plane (i.e., from medial to lateral). The moment was reduced with the lateral sagittal axis configuration and augmented with the medial sagittal axis configuration. Conclusions: The study results confirm the hypothesis of a direct correlation between the coronal location of the center of pressure and the magnitude of the knee adduction moment.
AB - Objectives: Footwear-generated biomechanical manipulations (e.g., wedge insoles) have been shown to reduce the magnitude of adduction moment about the knee. The theory behind wedged insoles is that a more laterally shifted location of the center of pressure reduces the distance between the ground reaction force and the center of the knee joint, thereby reducing adduction moment during gait. However, the relationship between the center of pressure and the knee adduction moment has not been studied previously. The aim of this study was to examine the association between the location of the center of pressure and the relative magnitude of the knee adduction moment during gait in healthy men. Methods: A novel foot-worn biomechanical device which allows controlled manipulation of the center of pressure location was utilized. Twelve healthy men underwent successive gait analysis testing in a controlled setting and with the device set to convey three different para-sagittal locations of the center of pressure: neutral, medial offset and lateral offset. Results: The knee adduction moment during the stance phase significantly correlated with the shift of the center of pressure from the functional neutral sagittal axis in the coronal plane (i.e., from medial to lateral). The moment was reduced with the lateral sagittal axis configuration and augmented with the medial sagittal axis configuration. Conclusions: The study results confirm the hypothesis of a direct correlation between the coronal location of the center of pressure and the magnitude of the knee adduction moment.
KW - Center of pressure
KW - Coronal kinetics of the knee
KW - Footwear-generated biomechanical manipulations
KW - Gait analysis
KW - Knee adduction moment
UR - http://www.scopus.com/inward/record.url?scp=53149097686&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2008.07.029
DO - 10.1016/j.jbiomech.2008.07.029
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:53149097686
SN - 0021-9290
VL - 41
SP - 3010
EP - 3016
JO - Journal of Biomechanics
JF - Journal of Biomechanics
IS - 14
ER -