TY - JOUR
T1 - Computer-generated real-time digital holography
T2 - First time use in clinical medical imaging
AU - Bruckheimer, Elchanan
AU - Rotschild, Carmel
AU - Dagan, Tamir
AU - Amir, Gabriel
AU - Kaufman, Aviad
AU - Gelman, Shaul
AU - Birk, Einat
N1 - Publisher Copyright:
© The Author 2016.
PY - 2016/8
Y1 - 2016/8
N2 - Aims Assessment of the feasibility of creating real-time interactive 3D digital holograms in a standard catheterization laboratory. 3D medical images are typically displayed and interacted with on 2D screens limiting their usefulness. A digital computer-generated real-time holographic display of patient's 3D data could provide a spatially accurate image with all the depth cues and afford interaction within the imageMethods We performed a feasibility study of creating real-time interactive 3D digital holograms with a purpose-built prototype and results using intraprocedural data from 3D rotational angiography and live 3D transesophageal echocardiography. The primary objective was to demonstrate that all the anatomical landmarks identified on standard imaging can be similarly identified using dynamic and static holographic images. The secondary objective was to demonstrate the usability of interactions with the image. Parameters were assessed by a rating scale. Eight patients were enrolled of whom five underwent transcatheter ASD closure using 3DTEE and three patients were evaluated by 3D rotational angiography. In all cases dynamic real-time and static 3D holograms were created in standard cath lab conditions. Four individual observers identified all anatomical landmarks on the holographic display independently from the 2D display. Interactions with the hologram including marking, cropping and rotation were performed. There were no adverse eventsConclusions This study demonstrates, for the first time, the feasibility of generating high quality, clinically relevant, 3D real-time colour dynamic holograms in a standard clinical setting with real patient volumetric data. The impact of computer-generated holography needs to be evaluated in controlled clinical trials.
AB - Aims Assessment of the feasibility of creating real-time interactive 3D digital holograms in a standard catheterization laboratory. 3D medical images are typically displayed and interacted with on 2D screens limiting their usefulness. A digital computer-generated real-time holographic display of patient's 3D data could provide a spatially accurate image with all the depth cues and afford interaction within the imageMethods We performed a feasibility study of creating real-time interactive 3D digital holograms with a purpose-built prototype and results using intraprocedural data from 3D rotational angiography and live 3D transesophageal echocardiography. The primary objective was to demonstrate that all the anatomical landmarks identified on standard imaging can be similarly identified using dynamic and static holographic images. The secondary objective was to demonstrate the usability of interactions with the image. Parameters were assessed by a rating scale. Eight patients were enrolled of whom five underwent transcatheter ASD closure using 3DTEE and three patients were evaluated by 3D rotational angiography. In all cases dynamic real-time and static 3D holograms were created in standard cath lab conditions. Four individual observers identified all anatomical landmarks on the holographic display independently from the 2D display. Interactions with the hologram including marking, cropping and rotation were performed. There were no adverse eventsConclusions This study demonstrates, for the first time, the feasibility of generating high quality, clinically relevant, 3D real-time colour dynamic holograms in a standard clinical setting with real patient volumetric data. The impact of computer-generated holography needs to be evaluated in controlled clinical trials.
KW - Echocardiography
KW - Rotational angiography
KW - Structural heart disease
KW - Three dimensional
UR - http://www.scopus.com/inward/record.url?scp=85015452394&partnerID=8YFLogxK
U2 - 10.1093/ehjci/jew087
DO - 10.1093/ehjci/jew087
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 27283456
AN - SCOPUS:85015452394
SN - 2047-2404
VL - 17
SP - 845
EP - 849
JO - European Heart Journal Cardiovascular Imaging
JF - European Heart Journal Cardiovascular Imaging
IS - 8
ER -