@article{1549af5af2f94b0f8cf946fdd4215b42,
title = "Comprehensive treatment of sphere-cap microelectrodes (SCMs) using digital simulations",
abstract = "The alternating direction implicit finite difference method (ADIFDM) is used to simulate the steady-state as well as the transient (chronoamperometric) behavior of sphere-cap microelectrodes (SCMs). The necessary steps to implement the ADIFDM for solving the rather complex geometry involved are described. The results for the steady-state behavior are in excellent agreement with a previously suggested analytical solution making the ADIFDM an excellent tool to develop a comprehensive theory for SCMs.",
keywords = "Alternating direction implicit finite difference method, Oblate hemispheroidal microelectrodes, Simulations, Sphere-cap microelectrodes",
author = "Yoram Selzer and Daniel Mandler",
note = "Funding Information: This research was supported by the Foundation for Basic Research administrated by the Israel Academy of Sciences and Humanities (597/97-1) and the Ministry of Science (8931).",
year = "1999",
month = dec,
day = "1",
doi = "10.1016/S1388-2481(99)00118-6",
language = "אנגלית",
volume = "1",
pages = "569--575",
journal = "Electrochemistry Communications",
issn = "1388-2481",
publisher = "Elsevier Inc.",
number = "12",
}