TY - JOUR
T1 - Comprehensive prospective cognitive and physical function assessment in elderly patients undergoing transcatheter aortic valve implantation
AU - Orvin, Katia
AU - Dvir, Danny
AU - Weiss, Avraham
AU - Assali, Abid
AU - Vaknin-Assa, Hana
AU - Shapira, Yaron
AU - Gazit, Osnat
AU - Sagie, Alex
AU - Kornowski, Ran
PY - 2014/3
Y1 - 2014/3
N2 - Objective: Transcatheter aortic valve implantation (TAVI) is occasionally associated with stroke and silent cerebral ischemia, which may affect cognitive and functional performance. The aim of this study was to evaluate the changes in cognitive performance and functional status following TAVI. Methods: We performed a comprehensive prospective functional, cognitive and quality of life (QOL) evaluation in consecutive patients who underwent TAVI using the CoreValve device (Medtronic Inc.). The evaluation was performed at baseline and 1 month after the procedure and included the 36-item Short-Form Health Survey for QOL assessment, Mini-Mental State Examination (MMSE), quantitative clock drawing test (Rouleau), color trails test, Cognistat evaluation, Barthel Index and Duke Activity Status Index. Results: A total of 36 patients completed the full pre- and post-TAVI evaluation. Mean age was 82.2 ± 4.2 years (52.8% men); 94.5% of patients had low functional class (New York Heart Association III/IV), and 13.9% had prior stroke. After the procedure, all patients had improved functional status and valve hemodynamics. At 1 month, there was a significant improvement in the MMSE and Cognistat evaluations (from 25.9 ± 3.3 to 27.6 ± 2.4, p < 0.001, and from 5 ± 1 to 5.7 ± 0.7, p = 0.001, respectively). Conclusions: Our preliminary results of a comprehensive assessment of patients undergoing TAVI indicate favorable results for both functional performance and cognitive function early after the procedure.
AB - Objective: Transcatheter aortic valve implantation (TAVI) is occasionally associated with stroke and silent cerebral ischemia, which may affect cognitive and functional performance. The aim of this study was to evaluate the changes in cognitive performance and functional status following TAVI. Methods: We performed a comprehensive prospective functional, cognitive and quality of life (QOL) evaluation in consecutive patients who underwent TAVI using the CoreValve device (Medtronic Inc.). The evaluation was performed at baseline and 1 month after the procedure and included the 36-item Short-Form Health Survey for QOL assessment, Mini-Mental State Examination (MMSE), quantitative clock drawing test (Rouleau), color trails test, Cognistat evaluation, Barthel Index and Duke Activity Status Index. Results: A total of 36 patients completed the full pre- and post-TAVI evaluation. Mean age was 82.2 ± 4.2 years (52.8% men); 94.5% of patients had low functional class (New York Heart Association III/IV), and 13.9% had prior stroke. After the procedure, all patients had improved functional status and valve hemodynamics. At 1 month, there was a significant improvement in the MMSE and Cognistat evaluations (from 25.9 ± 3.3 to 27.6 ± 2.4, p < 0.001, and from 5 ± 1 to 5.7 ± 0.7, p = 0.001, respectively). Conclusions: Our preliminary results of a comprehensive assessment of patients undergoing TAVI indicate favorable results for both functional performance and cognitive function early after the procedure.
KW - Aortic stenosis
KW - Cognitive function
KW - Quality of life
KW - Transcatheter aortic valve implantation
UR - http://www.scopus.com/inward/record.url?scp=84893205104&partnerID=8YFLogxK
U2 - 10.1159/000356696
DO - 10.1159/000356696
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 24481462
AN - SCOPUS:84893205104
SN - 0008-6312
VL - 127
SP - 227
EP - 235
JO - Cardiology
JF - Cardiology
IS - 4
ER -