T1 - Compensation for unconstrained catheter shaft motion in cardiac catheters
AU - Degirmenci, Alperen
AU - Loschak, Paul M.
AU - Tschabrunn, Cory M.
AU - Anter, Elad
AU - Howe, Robert D.
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/6/8
Y1 - 2016/6/8
N2 - Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures.
AB - Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures.
UR - http://www.scopus.com/inward/record.url?scp=84977526410&partnerID=8YFLogxK
U2 - 10.1109/ICRA.2016.7487643
DO - 10.1109/ICRA.2016.7487643
M3 - ???researchoutput.researchoutputtypes.contributiontobookanthology.conference???
AN - SCOPUS:84977526410
T3 - Proceedings - IEEE International Conference on Robotics and Automation
SP - 4436
EP - 4442
BT - 2016 IEEE International Conference on Robotics and Automation, ICRA 2016
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2016 IEEE International Conference on Robotics and Automation, ICRA 2016
Y2 - 16 May 2016 through 21 May 2016
ER -