T1 - Comparison of sirolimus eluting stent with bioresorbable polymer to everolimus eluting stent with permanent polymer in bifurcation lesions
T2 - Results from CENTURY II trial
AU - Orvin, K.
AU - Carrie, D.
AU - Richardt, G.
AU - Desmet, W.
AU - Assali, A.
AU - Werner, G.
AU - Ikari, Y.
AU - Fujii, K.
AU - Goicolea, J.
AU - Dangoisse, V.
AU - Manari, A.
AU - Saito, S.
AU - Wijns, W.
AU - Kornowski, R.
N1 - Publisher Copyright:
© 2015 Wiley Periodicals, Inc.
PY - 2016/5/1
Y1 - 2016/5/1
N2 - Objective To demonstrate the safety and efficacy of a new sirolimus eluting stent with bioresorbable polymer, Ultimaster, (BP-SES) compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in bifurcation lesions with respect to the freedom from Target Lesion Failure at 1-year. Methods Within 1,119 patients enrolled in the CENTURY II randomized controlled multicenter trial, 194 patients were treated for bifurcation lesions and randomized to either BP-SES (n = 95) or PP-EES (n = 99). The primary endpoint was freedom from target lesion failure (TLF) composite endpoint [cardiac death, MI not clearly attributable to a non-target vessel, and clinically driven target lesion revascularization (TLR)] at 1-year. Results Baseline patient demographic, angiographic, and stenting characteristics were similar in both study arms. A single stent technique with provisional or "cross over" stenting were the most widely used in both arms (93.2% BP-SES vs. 92.4% PP-EES). Freedom from TLF at 1-year was 94.7% for BP-SES and 91.9% for PP-EES (P for noninferiority 0.031). The rate of clinically driven target lesion revascularization (TLR) at 1-year was 3.2% for BP-SES and 3.0% for PP-EES (P = 0.95). There were no significant differences detected in any of the individual clinical endpoints or other secondary clinical endpoints between the study arms at 1-year follow up. Conclusions The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting in the treatment of patients with bifurcation lesions at 1-year follow up.
AB - Objective To demonstrate the safety and efficacy of a new sirolimus eluting stent with bioresorbable polymer, Ultimaster, (BP-SES) compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in bifurcation lesions with respect to the freedom from Target Lesion Failure at 1-year. Methods Within 1,119 patients enrolled in the CENTURY II randomized controlled multicenter trial, 194 patients were treated for bifurcation lesions and randomized to either BP-SES (n = 95) or PP-EES (n = 99). The primary endpoint was freedom from target lesion failure (TLF) composite endpoint [cardiac death, MI not clearly attributable to a non-target vessel, and clinically driven target lesion revascularization (TLR)] at 1-year. Results Baseline patient demographic, angiographic, and stenting characteristics were similar in both study arms. A single stent technique with provisional or "cross over" stenting were the most widely used in both arms (93.2% BP-SES vs. 92.4% PP-EES). Freedom from TLF at 1-year was 94.7% for BP-SES and 91.9% for PP-EES (P for noninferiority 0.031). The rate of clinically driven target lesion revascularization (TLR) at 1-year was 3.2% for BP-SES and 3.0% for PP-EES (P = 0.95). There were no significant differences detected in any of the individual clinical endpoints or other secondary clinical endpoints between the study arms at 1-year follow up. Conclusions The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting in the treatment of patients with bifurcation lesions at 1-year follow up.
KW - Sirolimus eluting stent
KW - cobalt-chromium stent
KW - complex lesions
KW - coronary bifurcation
KW - drug eluting stent
UR - http://www.scopus.com/inward/record.url?scp=84939639651&partnerID=8YFLogxK
U2 - 10.1002/ccd.26150
DO - 10.1002/ccd.26150
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 26268482
AN - SCOPUS:84939639651
SN - 1522-1946
VL - 87
SP - 1092
EP - 1100
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - 6