TY - JOUR
T1 - Comparison of balloon-expandable vs. self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation
T2 - From the CENTER-collaboration
AU - Vlastra, Wieneke
AU - Chandrasekhar, Jaya
AU - Muñoz-Garcia, Antonio J.
AU - Tchétché, Didier
AU - De Brito, Fabio S.
AU - Barbanti, Marco
AU - Kornowski, Ran
AU - Latib, Azeem
AU - D'Onofrio, Augusto
AU - Ribichini, Flavio
AU - Baan, Jan
AU - Tijssen, Jan G.P.
AU - Trillo-Nouche, Ramiro
AU - Dumonteil, Nicolas
AU - Abizaid, Alexandre
AU - Sartori, Samantha
AU - D'Errigo, Paola
AU - Tarantini, Giuseppe
AU - Lunardi, Mattia
AU - Orvin, Katia
AU - Pagnesi, Matteo
AU - Del Valle, Raquel
AU - Modine, Thomas
AU - Dangas, George
AU - Mehran, Roxana
AU - Piek, Jan J.
AU - Delewi, Ronak
N1 - Publisher Copyright:
© 2018 The Author(s). All rights reserved.
PY - 2019/2/1
Y1 - 2019/2/1
N2 - Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BEvalves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N= 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SEvalves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.
AB - Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BEvalves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N= 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SEvalves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.
KW - Balloon-expandable valve
KW - Edwards Sapien
KW - Medtronic CoreValve
KW - Self-expandable valve
KW - Stroke
KW - Transcatheter aortic valve implantation
KW - Transcatheter aortic valve replacement
UR - http://www.scopus.com/inward/record.url?scp=85061000552&partnerID=8YFLogxK
U2 - 10.1093/eurheartj/ehy805
DO - 10.1093/eurheartj/ehy805
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 30590565
AN - SCOPUS:85061000552
SN - 0195-668X
VL - 40
SP - 456
EP - 465
JO - European Heart Journal
JF - European Heart Journal
IS - 5
ER -