Comparison between single- And multi-sensor oesophageal temperature probes during atrial fibrillation ablation: Thermodynamic characteristics

  • Cory M. Tschabrunn
  • , Joshua Silverstein
  • , Tyler Berzin
  • , Ethan Ellis
  • , Alfred E. Buxton
  • , Mark E. Josephson
  • , Elad Anter*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

49 Scopus citations

Abstract

Aims Oesophageal temperature monitoring with single-sensor probe (SSP) has a variable ability to predict oesophageal ulceration as a consequence of pulmonary vein isolation (PVI). Multi-sensor self-expandable probes (MSPs) may offer improved thermal monitoring. The objective of this study was to compare the thermodynamic characteristics of both probes during PVI. Methods and results This prospective study enrolled 20 patients undergoing index PVI. Ten patients (group A) underwent dual monitoring with SSP and MSP and 10 control patients (group B) were monitored with SSP alone. Time to initial rise (>0.2°C), time to 1.0°C rise, peak temperature, and decay were recorded with each posterior wall lesion (20W, 198 applications). The operator was blinded to the MSP temperature data and ablation was only interrupted when SSP temperature increased by ≥2°C. All patients underwent endoscopy within 24 h. Initial temperature increase was detected earlier with MSP (13.4±7.5 vs. 30.5±15.4 s; P < 0.001); led to shorter time to 1.0°C rise (18.5±10.1 vs. 32.1±12.0 s; P < 0.001); and higher change in peak temperature (1.6±2.0 vs. 0.60±0.538C; P < 0.001). Decay time was similar between the probes (146.1±35.3 vs. 150.4±48.4 s; P = 0.89). The incidence of oesophageal ulceration was similar between the Groups A and B (5 and 4, respectively). Multi-sensor self-expandable probe provided greater sensitivity (100 vs. 60%) and similar specificity (60%) for detection of oesophageal ulceration. Five swine underwent oesophageal mapping before and after MSP placement without alteration in size or position. Conclusion Multi-sensor probes provide a superior thermodynamic profile. Its clinical value in reducing oesophageal injury requires further evaluation.

Original languageEnglish
Pages (from-to)891-897
Number of pages7
JournalEuropace
Volume17
Issue number6
DOIs
StatePublished - 1 Jun 2015
Externally publishedYes

Keywords

  • Atrial fibrillation
  • Multi-sensor probe
  • Oesophageal injury
  • Oesophageal temperature monitoring
  • Pulmonary vein isolation
  • Single-sensor probe

Fingerprint

Dive into the research topics of 'Comparison between single- And multi-sensor oesophageal temperature probes during atrial fibrillation ablation: Thermodynamic characteristics'. Together they form a unique fingerprint.

Cite this