Comparative assessment of different methods for the estimation of gait temporal parameters using a single inertial sensor: Application to elderly, post-stroke, Parkinson's disease and Huntington's disease subjects

Diana Trojaniello*, Andrea Ravaschio, Jeffrey M. Hausdorff, Andrea Cereatti

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

114 Scopus citations

Abstract

The estimation of gait temporal parameters with inertial measurement units (IMU) is a research topic of interest in clinical gait analysis. Several methods, based on the use of a single IMU mounted at waist level, have been proposed for the estimate of these parameters showing satisfactory performance when applied to the gait of healthy subjects. However, the above mentioned methods were developed and validated on healthy subjects and their applicability in pathological gait conditions was not systematically explored. We tested the three best performing methods found in a previous comparative study on data acquired from 10 older adults, 10 hemiparetic, 10 Parkinson's disease and 10 Huntington's disease subjects. An instrumented gait mat was used as gold standard. When pathological populations were analyzed, missed or extra events were found for all methods and a global decrease of their performance was observed to different extents depending on the specific group analyzed. The results revealed that none of the tested methods outperformed the others in terms of accuracy of the gait parameters determination for all the populations except the Parkinson's disease subjects group for which one of the methods performed better than others. The hemiparetic subjects group was the most critical group to analyze (stride duration errors between 4-5 % and step duration errors between 8-13 % of the actual values across methods). Only one method provides estimates of the stance and swing durations which however should be interpreted with caution in pathological populations (stance duration errors between 6-14 %, swing duration errors between 10-32 % of the actual values across populations).

Original languageEnglish
Pages (from-to)310-316
Number of pages7
JournalGait and Posture
Volume42
Issue number3
DOIs
StatePublished - 1 Sep 2015

Funding

FundersFunder number
7th Framework Program278169
European Commission

    Keywords

    • Accelerometry
    • Gait events
    • Inertial sensor
    • Temporal parameters
    • Trunk

    Fingerprint

    Dive into the research topics of 'Comparative assessment of different methods for the estimation of gait temporal parameters using a single inertial sensor: Application to elderly, post-stroke, Parkinson's disease and Huntington's disease subjects'. Together they form a unique fingerprint.

    Cite this