TY - JOUR
T1 - Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker system
AU - Dubinsky-Pertzov, Biana
AU - Hecht, Idan
AU - Gazit, Inbal
AU - Or, Lior
AU - Mahler, Ori
AU - Rotman, Shlomo
AU - Pras, Eran
AU - Einan-Lifshitz, Adi
N1 - Publisher Copyright:
© 2020, Springer Nature B.V.
PY - 2020/12
Y1 - 2020/12
N2 - Purpose: To report the clinical outcomes of patients who underwent cataract surgery with implantation of Ankoris monofocal toric intraocular lens (IOL) (PhysIOL SA, Liège, Belgium) using the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA). Methods: We conducted a retrospective case series of patients who underwent routine cataract extraction and implantation of Ankoris toric IOL using the Zeiss Callisto eye between January 2018 and December 2018 by four senior surgeons. Patients’ medical records were reviewed, and clinical outcomes including postoperative refraction, visual acuity outcomes, IOL position and deviation from planned axis were collected. Results: Fifty-six eyes of 56 patients were included, 48% were female, and the mean age was 70 ± 8 years. Patients with pseudoexfoliation syndrome, glaucoma or keratoconus were excluded from the study. Pre-operative mean corneal astigmatism was 2.38 ± 0.78 diopters (D), and mean implanted IOL cylindrical power was 3.06 ± 1.07 D. IOL rotation 30 days postoperatively was within 5° in 82% of eyes and between 6° and 10° in 10.8% of eyes. Mean postoperative refractive astigmatism 30 days postoperatively was 0.22 ± 0.36 D; in 84% of eyes the postoperative refractive astigmatism was ≤ 0.50 D. IOL rotation significantly increased between day 1 to day 7 postoperatively (1.91 ± 3.15° to 3.18 ± 3.3°, P = 0.001). However, no significant rotation had occurred between day 7 and day 30 postoperatively (P = 0.093). Conclusion: Cataract surgery with implantation of Ankoris monofocal toric IOL using the Zeiss Callisto Eye marking system is predictable and effective in reducing refractive astigmatism.
AB - Purpose: To report the clinical outcomes of patients who underwent cataract surgery with implantation of Ankoris monofocal toric intraocular lens (IOL) (PhysIOL SA, Liège, Belgium) using the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA). Methods: We conducted a retrospective case series of patients who underwent routine cataract extraction and implantation of Ankoris toric IOL using the Zeiss Callisto eye between January 2018 and December 2018 by four senior surgeons. Patients’ medical records were reviewed, and clinical outcomes including postoperative refraction, visual acuity outcomes, IOL position and deviation from planned axis were collected. Results: Fifty-six eyes of 56 patients were included, 48% were female, and the mean age was 70 ± 8 years. Patients with pseudoexfoliation syndrome, glaucoma or keratoconus were excluded from the study. Pre-operative mean corneal astigmatism was 2.38 ± 0.78 diopters (D), and mean implanted IOL cylindrical power was 3.06 ± 1.07 D. IOL rotation 30 days postoperatively was within 5° in 82% of eyes and between 6° and 10° in 10.8% of eyes. Mean postoperative refractive astigmatism 30 days postoperatively was 0.22 ± 0.36 D; in 84% of eyes the postoperative refractive astigmatism was ≤ 0.50 D. IOL rotation significantly increased between day 1 to day 7 postoperatively (1.91 ± 3.15° to 3.18 ± 3.3°, P = 0.001). However, no significant rotation had occurred between day 7 and day 30 postoperatively (P = 0.093). Conclusion: Cataract surgery with implantation of Ankoris monofocal toric IOL using the Zeiss Callisto Eye marking system is predictable and effective in reducing refractive astigmatism.
KW - Astigmatism
KW - Cataract
KW - IOL
KW - IOL rotation
KW - Toric IOL
UR - http://www.scopus.com/inward/record.url?scp=85088664552&partnerID=8YFLogxK
U2 - 10.1007/s10792-020-01511-4
DO - 10.1007/s10792-020-01511-4
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 32720169
AN - SCOPUS:85088664552
SN - 0165-5701
VL - 40
SP - 3259
EP - 3267
JO - International Ophthalmology
JF - International Ophthalmology
IS - 12
ER -