TY - JOUR
T1 - Casting doubt on the value of assessing the cardiac index in pregnancy
AU - Ram, Maya
AU - Lavie, Anat
AU - Lev, Shaul
AU - Blecher, Yair
AU - Amikam, Uri
AU - Shulman, Yael
AU - Avnon, Tomer
AU - Weiner, Eran
AU - Many, Ariel
N1 - Publisher Copyright:
© 2017, © 2017 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2018/12/2
Y1 - 2018/12/2
N2 - Objectives: The objective of this study is to assess the reliability of the cardiac index (CI) in healthy pregnant women at term by investigating the correlation between the cardiac output (CO) and the body surface area (BSA) using a novel non-invasive cardiography technique (NICaS™). Methods: Sixty-one healthy, normotensive women with a singleton pregnancy at term (≥37 gestational weeks) participated in this prospective observational study between 1/2015 and 6/2015 L. Each woman was assessed for CO by the NICaS™, an impedance device that non-invasively measures the CO and its derivatives. The NICaS™ demonstrated a very good correlation with the gold standard Swan–Ganz catheter. BSA was determined by the Dubois nomogram. Results: The mean ± standard deviation maternal age was 34.2 ± 5.3 years, mean height 166 ± 6 cm, and mean body mass index 23.9 ± 4.9 kg/m2. The mean gestational age was 38.8 ± 0.7 weeks. The correlation between the CO and the BSA was poor (Pearson r = 0.254, p <.005). Conclusions: The current study demonstrated poor correlation between the CO and the BSA in pregnant women, therefore, making the CI a non-reliable variable for assessing CO in pregnant women. We, therefore, suggest that the CO rather than the CI is the preferred parameter for hemodynamic measurements in this population.
AB - Objectives: The objective of this study is to assess the reliability of the cardiac index (CI) in healthy pregnant women at term by investigating the correlation between the cardiac output (CO) and the body surface area (BSA) using a novel non-invasive cardiography technique (NICaS™). Methods: Sixty-one healthy, normotensive women with a singleton pregnancy at term (≥37 gestational weeks) participated in this prospective observational study between 1/2015 and 6/2015 L. Each woman was assessed for CO by the NICaS™, an impedance device that non-invasively measures the CO and its derivatives. The NICaS™ demonstrated a very good correlation with the gold standard Swan–Ganz catheter. BSA was determined by the Dubois nomogram. Results: The mean ± standard deviation maternal age was 34.2 ± 5.3 years, mean height 166 ± 6 cm, and mean body mass index 23.9 ± 4.9 kg/m2. The mean gestational age was 38.8 ± 0.7 weeks. The correlation between the CO and the BSA was poor (Pearson r = 0.254, p <.005). Conclusions: The current study demonstrated poor correlation between the CO and the BSA in pregnant women, therefore, making the CI a non-reliable variable for assessing CO in pregnant women. We, therefore, suggest that the CO rather than the CI is the preferred parameter for hemodynamic measurements in this population.
KW - Body surface area
KW - cardiac output
KW - cesarean section
KW - hemodynamics
UR - http://www.scopus.com/inward/record.url?scp=85028541868&partnerID=8YFLogxK
U2 - 10.1080/14767058.2017.1364720
DO - 10.1080/14767058.2017.1364720
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 28805112
AN - SCOPUS:85028541868
SN - 1476-7058
VL - 31
SP - 3080
EP - 3084
JO - Journal of Maternal-Fetal and Neonatal Medicine
JF - Journal of Maternal-Fetal and Neonatal Medicine
IS - 23
ER -