Abstract
Aim: Current ex vivo study compared fracture resistance of teeth instrumented using 5 endodontic files, filled with Gutta-percha and AH Plus. Materials and Methods: Sixty freshly extracted, single-rooted mandibular premolars were acquired and decoronated to obtain 15 mm segments. These samples were randomly divided into six groups (n = 10). Group 1 served as the control containing untreated samples (without instrumentation or filling). In Groups 2-6, samples were instrumented using rotary (Universal ProTaper and Revo-S), reciprocating (WaveOne and RECIPROC ), and self-adjusting file (SAF), respectively. Following instrumentation, the samples were filled by lateral compaction with Gutta-percha and AH Plus. A week later, after the sealer was completely set, a vertical load was applied to the specimen′s canal in each group until fracture. The loads required for fracture were recorded, and statistical analysis was performed. Results: The mean fracture load differed significantly among the groups (P < 0.01; one-way ANOVA). Tukey′s post-hoc tests revealed that the fracture resistance was similar in the control and SAF groups (P > 0.05) and was significantly higher than that of the 2 rotary and reciprocating groups (P < 0.01). Conclusion: The samples instrumented by the SAF exhibited a better fracture resistance.
Original language | English |
---|---|
Pages (from-to) | 138-142 |
Number of pages | 5 |
Journal | Journal of Conservative Dentistry |
Volume | 19 |
Issue number | 2 |
DOIs | |
State | Published - 1 Mar 2016 |
Keywords
- Fracture strength
- Instrumentation
- ProTaper
- RECIPROC
- Revo-S
- Self-adjusting file
- WaveOne