TY - JOUR
T1 - An 18-month comparison of clinical outcomes between continuous-flow left ventricular assist devices
AU - Ben Zadok, Osnat Itzhaki
AU - Ben-Avraham, Ben
AU - Shaul, Aviv
AU - Hammer, Yoav
AU - Rubachevski, Victor
AU - Aravot, Dan
AU - Kornowski, Ran
AU - Ben-Gal, Tuvia
N1 - Publisher Copyright:
© 2019 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
PY - 2019/12/1
Y1 - 2019/12/1
N2 - OBJECTIVES: In this study, we aimed to determine the comparative outcomes of patients supported with continuous-flow left ventricular assist devices (LVADs): HeartMate 2 (HM2), HeartWare (HW) and HeartMate 3 (HM3) in a real-world setting. METHODS: The study was an investigator-initiated comparative retrospective analysis of patients who underwent continuous-flow LVAD implantation at our institution between 2008 and 2017. The follow-up duration was 18 months after implantation. RESULTS: The study included 105 continuous-flow LVAD-supported patients of whom 51% (n = 54), 24% (25) and 25% (26) underwent implantation of HM2, HW and HM3, respectively. During follow-up, patients who were supported with HM3 versus either HM2 or HW LVADs demonstrated a lower risk of stroke (0% vs 26%, P < 0.001 and 0% vs 40%, P < 0.001, respectively) and lower rates of thrombosis (0% vs 31%, P < 0.001 and 0% vs 12%, P < 0.001, respectively), findings that were consistent with their calculated haemocompatibility scores (cumulative score 5, 89 and 56 for HM3, HM2 and HW, respectively, P < 0.001). Moreover, patients supported with HM3 versus HW had fewer unplanned hospitalizations [median 1 (25th-75th interquartile range 0-2) vs 3 (interquartile range 2-4), P = 0.012]. Importantly, survival free from stroke or device exchange was higher in patients supported with HM3 compared with either the HM2 or the HW LVADs [hazard ratio (HR) 2.77, confidence interval (CI) 1.13-6.78; P = 0.026 and HR 2.70, CI 1.01-7.20; P = 0.047, respectively]. CONCLUSIONS: HM3 device currently presents better prognostic and adverse events profiles when compared with the HM2 or the HW LVADs. A larger-scale head-to-head comparison between the devices is warranted in order to confirm our findings.
AB - OBJECTIVES: In this study, we aimed to determine the comparative outcomes of patients supported with continuous-flow left ventricular assist devices (LVADs): HeartMate 2 (HM2), HeartWare (HW) and HeartMate 3 (HM3) in a real-world setting. METHODS: The study was an investigator-initiated comparative retrospective analysis of patients who underwent continuous-flow LVAD implantation at our institution between 2008 and 2017. The follow-up duration was 18 months after implantation. RESULTS: The study included 105 continuous-flow LVAD-supported patients of whom 51% (n = 54), 24% (25) and 25% (26) underwent implantation of HM2, HW and HM3, respectively. During follow-up, patients who were supported with HM3 versus either HM2 or HW LVADs demonstrated a lower risk of stroke (0% vs 26%, P < 0.001 and 0% vs 40%, P < 0.001, respectively) and lower rates of thrombosis (0% vs 31%, P < 0.001 and 0% vs 12%, P < 0.001, respectively), findings that were consistent with their calculated haemocompatibility scores (cumulative score 5, 89 and 56 for HM3, HM2 and HW, respectively, P < 0.001). Moreover, patients supported with HM3 versus HW had fewer unplanned hospitalizations [median 1 (25th-75th interquartile range 0-2) vs 3 (interquartile range 2-4), P = 0.012]. Importantly, survival free from stroke or device exchange was higher in patients supported with HM3 compared with either the HM2 or the HW LVADs [hazard ratio (HR) 2.77, confidence interval (CI) 1.13-6.78; P = 0.026 and HR 2.70, CI 1.01-7.20; P = 0.047, respectively]. CONCLUSIONS: HM3 device currently presents better prognostic and adverse events profiles when compared with the HM2 or the HW LVADs. A larger-scale head-to-head comparison between the devices is warranted in order to confirm our findings.
KW - Heart failure
KW - HeartMate3
KW - Left ventricular assist devices
KW - Prognosis
UR - http://www.scopus.com/inward/record.url?scp=85075223993&partnerID=8YFLogxK
U2 - 10.1093/ejcts/ezz268
DO - 10.1093/ejcts/ezz268
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 31566245
AN - SCOPUS:85075223993
SN - 1010-7940
VL - 56
SP - 1054
EP - 1061
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 6
ER -