TY - JOUR
T1 - Adjustability and Adaptability Are Critical Characteristics of Pediatric Support Surfaces
AU - Levy, Ayelet
AU - Kopplin, Kara
AU - Gefen, Amit
PY - 2015/10/1
Y1 - 2015/10/1
N2 - Significance: Pressure ulcers (PUs) in newborns and children are remarkably different from those in adults, both in their possible causal factors and in the etiology and biomechanical pathways for tissue damage. Recent Advances: Pediatric muscle and fat tissue structures are overall softer than those of adults, making newborns and young children more susceptible to deformation-inflicted injuries at their weight-bearing soft tissues. Critical Issues: The unique medical environment of neonatal and pediatric intensive care units, which is overloaded with medical devices, wiring, tubing, electrodes, and so on, is, in fact, an extrinsic risk factor for device-related PUs, since accidently misplaced tubes, wires, or electrodes can become trapped between the skin and the mattress, causing large sustained soft tissue deformations around them. Future Directions: Mattresses that are being used in neonatal and pediatric intensive care units must be able to respond to frequent movements and changing positions and also be able to effectively adapt and conform around such misplaced tubing or wires, which might contact the body and deform soft tissues. We used computer simulations of a tube caught under a preterm neonate's arm in a supine position to illustrate what adaptability of the support surface means in such cases. Our present simulations indicate that an air-cell-based technology provides considerably better protection against PUs in such cases, as the air-cells are able to locally buckle and conform around objects that are stiffer than the pediatric tissues (e.g., wires, tubes, electrodes), which minimizes exposure to tissue deformations.
AB - Significance: Pressure ulcers (PUs) in newborns and children are remarkably different from those in adults, both in their possible causal factors and in the etiology and biomechanical pathways for tissue damage. Recent Advances: Pediatric muscle and fat tissue structures are overall softer than those of adults, making newborns and young children more susceptible to deformation-inflicted injuries at their weight-bearing soft tissues. Critical Issues: The unique medical environment of neonatal and pediatric intensive care units, which is overloaded with medical devices, wiring, tubing, electrodes, and so on, is, in fact, an extrinsic risk factor for device-related PUs, since accidently misplaced tubes, wires, or electrodes can become trapped between the skin and the mattress, causing large sustained soft tissue deformations around them. Future Directions: Mattresses that are being used in neonatal and pediatric intensive care units must be able to respond to frequent movements and changing positions and also be able to effectively adapt and conform around such misplaced tubing or wires, which might contact the body and deform soft tissues. We used computer simulations of a tube caught under a preterm neonate's arm in a supine position to illustrate what adaptability of the support surface means in such cases. Our present simulations indicate that an air-cell-based technology provides considerably better protection against PUs in such cases, as the air-cells are able to locally buckle and conform around objects that are stiffer than the pediatric tissues (e.g., wires, tubes, electrodes), which minimizes exposure to tissue deformations.
U2 - 10.1089/wound.2015.0639
DO - 10.1089/wound.2015.0639
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.systematicreview???
C2 - 26487980
SN - 2162-1918
VL - 4
SP - 615
EP - 622
JO - Advances in Wound Care
JF - Advances in Wound Care
IS - 10
ER -