Active delivery cable tuned to device deployment state: Enhanced visibility of nitinol occluders during preclinical interventional MRI

Jamie A. Bell, Christina E. Saikus, Kanishka Ratnayaka, Israel M. Barbash, Anthony Z. Faranesh, Dominique N. Franson, Merdim Sonmez, Michael C. Slack, Robert J. Lederman*, Ozgur Kocaturk

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Purpose: To develop an active delivery system that enhances visualization of nitinol cardiac occluder devices during deployment under real-time magnetic resonance imaging (MRI). Materials and Methods: We constructed an active delivery cable incorporating a loopless antenna and a custom titanium microscrew to secure the occluder devices. The delivery cable was tuned and matched to 50Ω at 64 MHz with the occluder device attached. We used real-time balanced steady state free precession in a wide-bore 1.5T scanner. Device-related images were reconstructed separately and combined with surface-coil images. The delivery cable was tested in vitro in a phantom and in vivo in swine using a variety of nitinol cardiac occluder devices. Results: In vitro, the active delivery cable provided little signal when the occluder device was detached and maximal signal with the device attached. In vivo, signal from the active delivery cable enabled clear visualization of occluder device during positioning and deployment. Device release resulted in decreased signal from the active cable. Postmortem examination confirmed proper device placement. Conclusion: The active delivery cable enhanced the MRI depiction of nitinol cardiac occluder devices during positioning and deployment, both in conventional and novel applications. We expect enhanced visibility to contribute to the effectiveness and safety of new and emerging MRI-guided treatments.

Original languageEnglish
Pages (from-to)972-978
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume36
Issue number4
DOIs
StatePublished - Oct 2012
Externally publishedYes

Funding

FundersFunder number
National Heart, Lung, and Blood InstituteZIAHL005062

    Keywords

    • active MRI devices
    • cardiac implants
    • interventional MRI
    • structural heart disease

    Fingerprint

    Dive into the research topics of 'Active delivery cable tuned to device deployment state: Enhanced visibility of nitinol occluders during preclinical interventional MRI'. Together they form a unique fingerprint.

    Cite this