T1 - Accuracy of the ultrasound biomicroscopy bag/balloon technique in locating horizontal extraocular muscle insertions before and after strabismus surgery
AU - Mezad-Koursh, Daphna
AU - Rosenblatt, Amir
AU - Cohen, Shai
AU - Neudorfer, Meira
AU - Keynan, Idit
AU - Stolovitch, Chaim
AU - Zur, Dinah
N1 - Publisher Copyright:
Copyright © SLACK Incorporated
PY - 2020/2
Y1 - 2020/2
N2 - Purpose: To investigate the accuracy of high frequency ultrasound biomicroscopy using the bag/balloon technique to locate recti muscle insertions before and after strabismus surgery. Methods: This was a prospective masked study. The distance from the limbus to horizontal recti muscle insertions was measured by caliper intraoperatively and ultrasound biomicroscopy preoperatively and during follow-up. Accuracy was defined as the difference between ultrasound biomicroscopy and caliper measurements. Results: Thirty-nine muscles (19 medial rectus and 20 lateral rectus) of 22 patients were included. The mean age of the patients was 34.7 ± 15.5 years (range: 18 to 78 years). Follow-up measurements were available for 25 muscles: 12 muscles were recessed and 13 were resected/ advanced. Twelve of the included muscles underwent prior surgery. There was a strong correlation between preoperative mean ultrasound biomicroscopy and caliper measurements (P < .001, rp = 0.872) without significant difference between the accuracy of identification of medial rectus and lateral rectus muscles (P = .116 and .377, respectively). On average, postoperative ultrasound biomicroscopy measurements of recessed muscles were 1.15 mm greater than caliper measurements at the end of surgery (P = .003), whereas the mean difference in the resected muscles was not statistically significant (-0.07 mm, P > .999). Overall, in 16 of 25 muscles (64%), the differences between the postoperative measurements and the end of surgery measurements were less than 1 mm. There was no correlation between the accuracy and the time of ultrasound biomicroscopy after surgery (P = .516). Conclusions: The ultrasound biomicroscopy bag/balloon technique is an accurate and reliable method of locating recti muscle insertions before and after strabismus surgery. Ultrasound biomicroscopy may assist strabismologists in planning repeated operations.
AB - Purpose: To investigate the accuracy of high frequency ultrasound biomicroscopy using the bag/balloon technique to locate recti muscle insertions before and after strabismus surgery. Methods: This was a prospective masked study. The distance from the limbus to horizontal recti muscle insertions was measured by caliper intraoperatively and ultrasound biomicroscopy preoperatively and during follow-up. Accuracy was defined as the difference between ultrasound biomicroscopy and caliper measurements. Results: Thirty-nine muscles (19 medial rectus and 20 lateral rectus) of 22 patients were included. The mean age of the patients was 34.7 ± 15.5 years (range: 18 to 78 years). Follow-up measurements were available for 25 muscles: 12 muscles were recessed and 13 were resected/ advanced. Twelve of the included muscles underwent prior surgery. There was a strong correlation between preoperative mean ultrasound biomicroscopy and caliper measurements (P < .001, rp = 0.872) without significant difference between the accuracy of identification of medial rectus and lateral rectus muscles (P = .116 and .377, respectively). On average, postoperative ultrasound biomicroscopy measurements of recessed muscles were 1.15 mm greater than caliper measurements at the end of surgery (P = .003), whereas the mean difference in the resected muscles was not statistically significant (-0.07 mm, P > .999). Overall, in 16 of 25 muscles (64%), the differences between the postoperative measurements and the end of surgery measurements were less than 1 mm. There was no correlation between the accuracy and the time of ultrasound biomicroscopy after surgery (P = .516). Conclusions: The ultrasound biomicroscopy bag/balloon technique is an accurate and reliable method of locating recti muscle insertions before and after strabismus surgery. Ultrasound biomicroscopy may assist strabismologists in planning repeated operations.
UR - http://www.scopus.com/inward/record.url?scp=85078280084&partnerID=8YFLogxK
U2 - 10.3928/01913913-20191115-01
DO - 10.3928/01913913-20191115-01
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 31972035
AN - SCOPUS:85078280084
SN - 0191-3913
VL - 57
SP - 12
EP - 20
JO - Journal of Pediatric Ophthalmology and Strabismus
JF - Journal of Pediatric Ophthalmology and Strabismus
IS - 1
ER -