Accuracy of the ultrasound biomicroscopy bag/balloon technique in locating horizontal extraocular muscle insertions before and after strabismus surgery

Daphna Mezad-Koursh*, Amir Rosenblatt, Shai Cohen, Meira Neudorfer, Idit Keynan, Chaim Stolovitch, Dinah Zur

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Purpose: To investigate the accuracy of high frequency ultrasound biomicroscopy using the bag/balloon technique to locate recti muscle insertions before and after strabismus surgery. Methods: This was a prospective masked study. The distance from the limbus to horizontal recti muscle insertions was measured by caliper intraoperatively and ultrasound biomicroscopy preoperatively and during follow-up. Accuracy was defined as the difference between ultrasound biomicroscopy and caliper measurements. Results: Thirty-nine muscles (19 medial rectus and 20 lateral rectus) of 22 patients were included. The mean age of the patients was 34.7 ± 15.5 years (range: 18 to 78 years). Follow-up measurements were available for 25 muscles: 12 muscles were recessed and 13 were resected/ advanced. Twelve of the included muscles underwent prior surgery. There was a strong correlation between preoperative mean ultrasound biomicroscopy and caliper measurements (P < .001, rp = 0.872) without significant difference between the accuracy of identification of medial rectus and lateral rectus muscles (P = .116 and .377, respectively). On average, postoperative ultrasound biomicroscopy measurements of recessed muscles were 1.15 mm greater than caliper measurements at the end of surgery (P = .003), whereas the mean difference in the resected muscles was not statistically significant (-0.07 mm, P > .999). Overall, in 16 of 25 muscles (64%), the differences between the postoperative measurements and the end of surgery measurements were less than 1 mm. There was no correlation between the accuracy and the time of ultrasound biomicroscopy after surgery (P = .516). Conclusions: The ultrasound biomicroscopy bag/balloon technique is an accurate and reliable method of locating recti muscle insertions before and after strabismus surgery. Ultrasound biomicroscopy may assist strabismologists in planning repeated operations.

Original languageEnglish
Pages (from-to)12-20
Number of pages9
JournalJournal of Pediatric Ophthalmology and Strabismus
Volume57
Issue number1
DOIs
StatePublished - Feb 2020

Fingerprint

Dive into the research topics of 'Accuracy of the ultrasound biomicroscopy bag/balloon technique in locating horizontal extraocular muscle insertions before and after strabismus surgery'. Together they form a unique fingerprint.

Cite this