A time domain measurements procedure of piezoelectric transformers equivalent scheme parameters

S. Ozeri, D. Shmilovitz

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

A time domain measurement based method of piezoelectric transformers model parameters is suggested. This method is simpler and assumes fewer measurements comparing to, commonly employed, admittance circle based procedures. In addition, the method proposed herein requires only standard laboratory equipment. An additional advantage of this method is the ability to test the PT at high voltage levels, providing better indication to the model parameter values that are in effect during actual operation of the device in a power converter.

Original languageEnglish
Title of host publicationISCAS 2006
Subtitle of host publication2006 IEEE International Symposium on Circuits and Systems, Proceedings
Pages2281-2284
Number of pages4
StatePublished - 2006
EventISCAS 2006: 2006 IEEE International Symposium on Circuits and Systems - Kos, Greece
Duration: 21 May 200624 May 2006

Publication series

NameProceedings - IEEE International Symposium on Circuits and Systems
ISSN (Print)0271-4310

Conference

ConferenceISCAS 2006: 2006 IEEE International Symposium on Circuits and Systems
Country/TerritoryGreece
CityKos
Period21/05/0624/05/06