Abstract
A time domain measurement based method of piezoelectric transformers model parameters is suggested. This method is simpler and assumes fewer measurements comparing to, commonly employed, admittance circle based procedures. In addition, the method proposed herein requires only standard laboratory equipment. An additional advantage of this method is the ability to test the PT at high voltage levels, providing better indication to the model parameter values that are in effect during actual operation of the device in a power converter.
Original language | English |
---|---|
Title of host publication | ISCAS 2006 |
Subtitle of host publication | 2006 IEEE International Symposium on Circuits and Systems, Proceedings |
Pages | 2281-2284 |
Number of pages | 4 |
State | Published - 2006 |
Event | ISCAS 2006: 2006 IEEE International Symposium on Circuits and Systems - Kos, Greece Duration: 21 May 2006 → 24 May 2006 |
Publication series
Name | Proceedings - IEEE International Symposium on Circuits and Systems |
---|---|
ISSN (Print) | 0271-4310 |
Conference
Conference | ISCAS 2006: 2006 IEEE International Symposium on Circuits and Systems |
---|---|
Country/Territory | Greece |
City | Kos |
Period | 21/05/06 → 24/05/06 |