A system for automatic aorta sections measurements on chest CT

Yitzchak Pfeffer, Arnaldo Mayer, Adi Zholkover, Eli Konen

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

A new method is proposed for caliber measurement of the ascending aorta (AA) and descending aorta (DA). A key component of the method is the automatic detection of the carina, as an anatomical landmark around which an axial volume of interest (VOI) can be defined to observe the aortic caliber. For each slice in the VOI, a linear profile line connecting the AA with the DA is found by pattern matching on the underlying intensity profile. Next, the aortic center position is found using Hough transform on the best linear segment candidate. Finally, region growing around the center provides an accurate segmentation and caliber measurement. We evaluated the algorithm on 113 sequential chest CT scans, slice thickness of 0.75 - 3.75mm, 90 with contrast agent injected. The algorithm success rates were computed as the percentage of scans in which the center of the AA was found. Automated measurements of AA caliber were compared with independent measurements of two experienced chest radiologists, comparing the absolute difference between the two radiologists with the absolute difference between the algorithm and each of the radiologists. The measurement stability was demonstrated by computing the STD of the absolute difference between the radiologists, and between the algorithm and the radiologists. Results: Success rates of 93% and 74% were achieved, for contrast injected cases and non-contrast cases, respectively. These results indicate that the algorithm can be robust in large variability of image quality, such as the cases in a realworld clinical setting. The average absolute difference between the algorithm and the radiologists was 1.85mm, lower than the average absolute difference between the radiologists, which was 2.1mm. The STD of the absolute difference between the algorithm and the radiologists was 1.5mm vs 1.6mm between the two radiologists. These results demonstrate the clinical relevance of the algorithm measurements.

Original languageEnglish
Title of host publicationMedical Imaging 2016
Subtitle of host publicationComputer-Aided Diagnosis
EditorsGeorgia D. Tourassi, Samuel G. Armato
PublisherSPIE
ISBN (Electronic)9781510600201
DOIs
StatePublished - 2016
EventMedical Imaging 2016: Computer-Aided Diagnosis - San Diego, United States
Duration: 28 Feb 20162 Mar 2016

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9785
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2016: Computer-Aided Diagnosis
Country/TerritoryUnited States
CitySan Diego
Period28/02/162/03/16

Keywords

  • Aneurysm
  • Aorta detection
  • Aorta segmentation
  • CAD
  • Chest CT
  • Dilated aorta
  • Supervised classifier

Fingerprint

Dive into the research topics of 'A system for automatic aorta sections measurements on chest CT'. Together they form a unique fingerprint.

Cite this