A direct measurement of the Z0 invisible width by single photon counting

M. Z. Akrawy, G. Alexander, J. Allison, P. P. Allport, K. J. Anderson, J. C. Armitage, G. T.J. Arnison, P. Ashton, G. Azuelos, J. T.M. Baines, A. H. Ball, J. Banks, G. J. Barker, R. J. Barlow, J. R. Batley, G. Beaudoin, A. Beck, J. Becker, T. Behnke, K. W. BellG. Bella, S. Bethke, O. Biebel, U. Binder, I. J. Boodworth, P. Bock, H. Breuker, R. M. Brown, R. Brun, A. Buijs, H. J. Burckhart, P. Capiluppi, R. K. Carnegie, A. A. Carter, J. R. Carter, C. Y. Chang, D. G. Charlton, J. T.M. Chrin, P. E.L. Clarke, I. Cohen, W. J. Collins, J. E. Conboy, M. Couch, M. Coupland, M. Cuffiani, S. Dado, G. M. Dallavalle, S. De Jong, P. Debu, M. M. Deninno, A. Dieckmann, M. Dittmar, M. S. Dixit, E. Duchovni, I. P. Duerdoth, D. J.P. Dumas, P. A. Elcombe, P. G. Estabrooks, E. Etzion, F. Fabbri, P. Farthouat, H. M. Fischer, D. G. Fong, M. T. French, C. Fukunaga, A. Gaidot, O. Ganel, J. W. Gary, J. Gascon, N. I. Geddes, C. N.P. Gee, C. Geich-Gimbel, S. W. Gensler, F. X. Gentit, G. Giacomelli, V. Gibson, W. R. Gibson, J. D. Gillies, J. Goldberg, M. J. Goodrick, W. Gorn, D. Granite, E. Gross, J. Grunhaus, H. Hagedorn, J. Hagemann, M. Hansroul, C. K. Hargrove, I. Harrus, J. Hart, P. M. Hattersley, M. Hauschild, C. M. Hawkes, E. Heflin, R. J. Hemingway, R. D. Heuer, J. C. Hill, S. J. Hillier, D. A. Hinshaw, C. Ho, J. D. Hobbs, P. R. Hobson, D. Hochman, B. Holl, R. J. Homer, S. R. Hou, C. P. Howarth, R. E. Hughes-Jones, R. Humbert, P. Igo-Kemenes, H. Ihssen, D. C. Imrie, L. Janissen, A. Jawahery, P. W. Jeffreys, H. Jeremie, M. Jimack, M. Jobes, R. W.L. Jones, P. Jovanovic, D. Karlen, K. Kawagoe, T. Kawamoto, R. G. Kellogg, B. W. Kennedy, C. Kleinwort, D. E. Klem, G. Knop, T. Kobayashi, T. P. Kokott, L. Köpke, R. Kowalewski, H. Kreutzmann, J. Kroll, M. Kuwano, P. Kyberd, G. D. Lafferty, F. Lamarche, W. J. Larson, J. G. Layter, P. Le Du, P. Leblanc, A. M. Lee, M. H. Lehto, D. Lellouch, P. Lennert, C. Leroy, L. Lessard, S. Levegrün, L. Levinson, S. L. Lloyd, F. K. Loebinger, J. M. Lorah, B. Lorazo, M. J. Losty, J. Ludwig, J. Ma, A. A. Macbeth, M. Mannelli, S. Marcellini, G. Maringer, A. J. Martin, J. P. Martin, T. Mashimo, P. Mättig, U. Maur, T. J. McMahon, J. R. McNutt, F. Meijers, D. Menszner, F. S. Merritt, H. Mes, A. Michelini, R. P. Middleton, G. Mikenberg, J. Mildenberger, D. J. Miller, C. Milstene, M. Minowa, W. Mohr, C. Moisan, A. Montanari, T. Mori, M. W. Moss, P. G. Murphy, W. J. Murray, B. Nellen, H. H. Nguyen, M. Nozaki, A. J.P. O'Dowd, S. W. O'Neale, B. P. O'Neill, F. G. Oakham, F. Odorici, M. Ogg, H. Oh, M. J. Oreglia, S. Orito, J. P. Pansart, G. N. Patrick, S. J. Pawley, P. Pfister, J. E. Pilcher, J. L. Pinfold, D. E. Plane, B. Poli, A. Pouladdej, E. Prebys, T. W. Pritchard, H. Przysiezniak, G. Quast, M. W. Redmond, D. L. Rees, M. Regimbald, K. Riles, C. M. Roach, S. A. Robins, A. Rollnik, J. M. Roney, S. Rossberg, A. M. Rossi, P. Routenburg, K. Runge, O. Runolfsson, S. Sanghera, R. A. Sansum, M. Sasaki, B. J. Saunders, A. D. Schaile, O. Schaile, W. Schappert, P. Scharff-Hansen, S. Schreiber, J. Schwarz, A. Shapira, B. C. Shen, P. Sherwood, A. Simon, P. Singh, G. P. Siroli, A. Skuja, A. M. Smith, T. J. Smith, G. A. Snow, R. W. Springer, M. Sproston, K. Stephens, H. E. Stier, R. Stroehmer, D. Strom, H. Takeda, T. Takeshita, P. Taras, N. J. Thackray, T. Tsukamoto, M. F. Turner, G. Tysarczyk-Niemeyer, D. Van den plas, R. Van Kooten, G. J. VanDalen, G. Vasseur, C. J. Virtue, H. von der Schmitt, J. von Krogh, A. Wagner, C. Wahl, J. P. Walker, C. P. Ward, D. R. Ward, P. M. Watkins, A. T. Watson, N. K. Watson, M. Weber, S. Weisz, P. S. Wells, N. Wermes, M. Waymann, G. W. Wilson, J. A. Wilson, I. Wingerter, V. H. Winterer, N. C. Wood, S. Wotton, T. R. Wyatt, R. Yaari, Y. Yang, G. Yekutieli, T. Yoshida, W. Zeuner, G. T. Zorn

Research output: Contribution to journalArticlepeer-review

Abstract

The OPAL detector at LEP is used to measure the branching ratio of the Z0 into invisible particles by measuring the cross section of single photon events in e+e- collisions at centre-of-mass energies near the Z0 resonance. In a data sample of 5.3 pb-1, we observe 73 events with single photons depositing more than 1.5 GeV in the electromagnetic calorimeter, with an expected background of 8±2 events not associated with invisible Z0 decay. With this data we determine the Z0 invisible width to be 0.50±0.07±0.03 GeV, where the first error is statistical and the second systematic. This corresponds to 3.0±0.4±0.2 light neutrino generations in the Standard Model.

Original languageEnglish
Pages (from-to)373-384
Number of pages12
JournalEuropean Physical Journal C
Volume50
Issue number3
DOIs
StatePublished - Sep 1991

Fingerprint

Dive into the research topics of 'A direct measurement of the Z0 invisible width by single photon counting'. Together they form a unique fingerprint.

Cite this